 Advanced Wide Angle Geometry (WAG™) optics provide high x-ray flux, which leads to optimal excitation conditions. Through the use of secondary targets with computer-varied voltages and emission currents, the EX-6600 provides polarized excitation energy, increased signal-to-noise ratio, superior sensitivity and selective excitation of elements. The near absence of background radiation produces extremely low detection limits. The Multi-Channel Acquisition resolution provides superior peak-to-background ratio for improved detector response.
Features
Some unique features of the EX-6600: - Close-coupled optics in the secondary target mode allow for greater flux and superior sensitivity - Eight customizable filters and eight secondary targets - To further enhance repeatability and reliability, the entire sampling chamber and analysis area are mechanically isolated and vibrationally dampened. - With our proprietary end window tube design, fewer secondary electrons impinge on the Be window. - The ultra-thin Be window provides superior performance for the low Z elements.
Specifications | | Excitation type | Direct with filters and secondary target | | Detector Type | New generation Si(Li) PIN Diode with Light Element Option window | | Detector Cooling | LN2 | | Coolant Sensor | Reports levels from 0-100% in 1% increments and includes a low LN2 alarm and automatic bias cut-off warning | | Dewar Capacity | 31 litres - typical refill cycle of more than 14 days | | Detector Resolution | 140eV +/-5eV at 5,9keV | Detector Window Thickness | Custom designed | | Tube Type | End window - front anode Rh-anode standard (optional Mo, W, Pt, Cr) | | Maximum tube potential | 60 kV (3~60 kV in 1 kV increments) | | Maximum tube power | 400 Watts | Elements analysed
| Na-U | | Number of tube filters | 8 software selectable filters; open, Cl, Ti, Fe, Cu, Mo, Rh, Sn | | Number of Secondary Targets | 8 (Mg, Si, Ti, Fe, Ge, Mo, Sn, Gd) | | Standard autosampler | 10-position; samples up to 47 mm in diameter | | Type of Analysis | Qualitative and Quantitative | | Computer | Integrated Data System | | Software | nEXt Windows based analytical software | | Power requirements | 115 or 230 V AC (1,2 or 0,6A respectively), 50/60Hz | | Dimensions | 84×57×102 cm (unpacked) 85x100x130 cm (packed) | | Weight | 230 kg(gr. weight) / 180 kg (net.weight) | | Data Processing and Storage | Advanced analog processor with gated baseline restorer, digital zero correction and software selectable time constants. 16-bit successive approximation analog to digital converter with integral 2048 channel multichannel analyser and digital peak detector. | | Options | Thermoelectrically cooled LN2--Free Detector Sample Spinner | | |  | This specification can be changed without prior notice |
|
|