EDXRF Spectrometers

EX-3600M

Features

Designed especially for difficult sample matrices, the EX-3600M gives customers a choice of advanced powerful options to optimize the instrument for your particular application. The result is a custom-built, high performance instrument, at a price less than that of a larger laboratory unit.
The EX-3600M's options include the specialized CLS (Custom Line Source) that increases excitation energy to specific hard-to-measure elements within the sample matrix.
The CLS option provides increased peak to background ratio and improved detection limits - a 5x improvement in the MDL for sodium (Na).
The ultra-sensitive LEO (Light Element Optimized) detector option affords a 10x improvement in the MDL for sodium (Na).
Analyzer is also available in a thermoelectrically cooled version - EX-3600M TEC.

Applications

Coal and coal ash analysis
3600M  can  be  used  for  such  as  the  oxides of  the elements: Si, Al, Fe, Ca. Mg, Na, K,  ti, Mn, S, P, Ba, Sr and Zn  in a coal sample. Concentrations of these elements can be used to determine the quality of the coal for petrochemical and energy use.
Cement & glass analysis
Cement is defined as any of a variety of substances used  for  bonding  or  settling  to  a  hard  material. Portland  cement,  currently  the  foundation  of modern industrial  construction  techniques,  is  a  mixture  of calcium  silicates  and  aluminates  made  by  heating limestone  with  clay  in  a  kiln.  The  resulting  material is  then  ground  to  a  fine  power  (cement). Controlling even  relatively  small  changes  in  the  composition  of cements  during  the  production  process  has  become a  high  priority  interest  for  manufacturers  worldwide. The  oxide  composition  of  glass  sand  determines
its  chemical  and  physical  properties.  The  premix components  composition  must  be  accurately  and precisely measured  in  order  to  determine  the  quality of the glass. 
Food & drug additives
Food  is  a market  that  offers many  opportunities for 3600. There are a number of minerals and mentals added for extra nutritional value that must be monitored to comply with Food and Drug Administration regulations.
CI in hydraulic oils
Waste  oils  such  as  used  lubrication  oil  are used  in  a  number  of  oil  power  plants and kilns.  These  are  monitored  for  elements:  S,  Cl, As,  Pb, Cd for  toxic metals  chlorine,  and  sulfur  per environmental  protection  agency  (EPA)  guidelines.

Specifications

Excitation type Direct (polychromatic)
Detector Type Si(Li)
Detector Cooling LN2
Detector Resolution 140eV +/-10eV at 5,9keV

Detector Window

Light Element window for optimal analysis of low z-elements
Tube Type

End window - front anode
Rh-anode standard (other tube options available)

Maximum tube potential 50 kV
Maximum tube power 50 Watts
Elements analyzed Na-U
Number of tube filters 8 software selectable filters; open, collimator, Ti, Cu, Fe, Mo, Rh, W
Filters can be optimized per application
Type of Analysis Qualitative, Quantitative & Semiquantitative using SLFP
Standard autosampler 10 samples (42mm max. diameter)
Computer Integrated Data System
High resolution color printer
Software nEXt Windows based analytical software
Power requirements 115 or 230 VAC (1,2 or 0,6A respectively), 50/60Hz
Dimensions 84×57×102 cm (unpacked)
85x100x130 cm (packed)
Weight 230 kg(gr. weight) / 180 kg (net.weight)
Options He-purge
LN2--Free Detector
Sample Spinner
18-position Sample Changer Tray (25 mm in diameter)

This specification can be changed without prior notice