Applications

Send message

WFX-210
wfx-210.jpg_2


Atomic Absorption Spectrometer WFX-210 with flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950oC with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range.


Features

Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor.

A flame emission burner head can be installed to perform flame emission analysis to akali metals as K, Na etc.

Accurate fully automated control system
Automatic 6-lamp turret, automatic adjustment of lamp current and optimization of light beam position.
Automatic wavelength scanning and peak picking.
Automatic spectral bandwidth changing.
Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, automatic ignition and automatic gas flow setting.

Reliable fully automatic graphite furnace analysis
Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%.
Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact.
Multi-function autosampler features automatic standard sample preparation, automatic correction of sampling probe depth, automatic tracing and correction of liquid surface height in the sample vessel, with the sampling accuracy of 1% and reproducibility of 0.3%, realizing fully automation of graphite furnace analysis.
Perfect safety protection measures
Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system.
Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and over-heating in graphite furnace system.

Advance and reliable electronic design
Adopting large-scale programmable logic array and Inter I2C bus technology.
European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.

 

Easy and practical analysis software
Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
Automatic sample dilution, automatic curve fitting, automatic sensitivity correction.
Automatic calculation of sample concentration (content), mean value, standard deviation and relative standard deviation calculation.
Mutil-elements determination in sequence to the same sample.
Measured data and final results can be printed out and edited in Excel format.

Characteristic mass of some elements using oxygen-rich air-C2H2 flame and other flame methods (Unit: ug/ml)

Element

Wavelength (nm)

Rich oxygen air - C2H2 flame

N2O - C2H2 flame

Air - C2H2 flame

Ca

422,7

0,009

0,05

0,07

Yb

378,8

0,037

0,08

7,6

Eu

459,4

0,137

0,3

3,0

Al

309,3

0,4

0,7

-

Sr

460,7

0,016

0,1

0,15

Ba

553,5

0,1

0,4

10,0

Mo

313,3

0,15

0,4

0,8

W

255,1

3,2

5,0

-

Ga

287,4

0,4

1,0

1,3

Sm

429,7

2,92

8,5

-

La

550,1

37,2

35,0

-

Sn

224,6

0,8

3,0

50

 

 

Specifications

Main SpecificationWavelength range190-900nm
Wavelength accuracy Better than ±0.25nm
ResolutionTwo spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability0.004A/30min
Background correctionThe D2 lamp background correction capability at 1A is better than 30 times.
The S-H background correction capability at 1.8A is better than 30 times.
Light Source SystemLamp turretMotorized 6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis).
Lamp current adjustment

Wide pulse current: 0~25mA,
Narrow pulse current: 0~10mA

Lamp power supply mode

400Hz square wave pulse;
100Hz narrow square wave pulse+400Hz wide square wave pulse.

Optical systemMonochromatorSingle beam, Czerny-Turner design grating monochromator
Grating1800l/mm
Focal length277mm
Blazed wavelength250nm
Spectral bandwidth0.1nm, 0.2nm, 0.4nm, 1.2nm, auto-switch over
Flame AtomizerBurner10 cm single slot all-titanium burner
Spray chamberCorrosion resistant all-plastic spray chamber
NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Emission burner provided
Graphite Furnace
Temperature rangeRoom temperature~3000ºC
Heating rate2000℃/s
Graphite tube dimensions28mm(L)×8mm(OD)
Characteristic massCd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
PrecisionCd≤3%, Cu≤3%, Mo≤4%
Detection and Data Processing SystemDetector R928 Photomultiplier with high sensitivity and wide spectral range.
SoftwareUnder Windows operating system
Analytical methodWorking curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
Repeat times1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task functionsSequential measurement for multi-element determination to the same sample
Condition readingWith model function.
Result printingMeasurement data and final analytical report printout, editing with Excel
Standard RS-232 serial port communication
Graphite Furnace AutosampleSample tray capacity55 sample vessels and 5 reagent vessels
Vessel materialPolypropylene
Vessel volume3ml for sample vessel, 20ml for reagent vessel
Minimum sampling volume1μl
Repeatable sampling times1 -99 times
Sampling systemAccurate dual pump system, with 100μl and 1ml injectors
Characteristic Concentration and Detection LimitAir-Acetylene
Oxygen-rich Air-C2H2 flame
Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Ba: Characteristic concentration ≤ 0.22mg/L
Al: Characteristic concentration ≤ 0.4mg/L
Function ExpansionHydride vapor generator can be connected for hydride analysis
Dimensions and weightMain unit107×49×58cm, 140kg
Graphite Furnace42×42×46cm, 65kg
Autosampler40×29×29cm, 15kg
 

This specification can be changed without prior notice